Uncertainty evaluation for calibration system for cryogenic thermistor thermometers(PDF)

《火箭推进》[ISSN:1672-9374/CN:CN 61-1436/V]

Issue:
2012年02期
Page:
75-78
Research Field:
测控与试验
Publishing date:

Info

Title:
Uncertainty evaluation for calibration system for cryogenic thermistor thermometers
Author(s):
DONG Xue YANG Xiao-yang LAN Yu-qi
Beijing Institute of Aerospace Testing Technology, Beijing 100074, China
Keywords:
cryogenic thermistor thermometers uncertainty evaluation calibra
PACS:
V423-34
DOI:
-
Abstract:
The measurement uncertainty of a calibration system for cryogenic thermistor thermometers applied to rocket engines is analyzed and computed according to the evaluation method of measurement uncertainty. Through the uncertainty evaluation of calibration results, the performance and error of the calibration system for cryogenic thermistor thermometers applied to rocket engines were mastered, and the gist of uncertainty evaluation was provided for the establishment, effectuation and exmaination of the metrological standard in national defense.

References:

[1]国家质量技术监督局. JJF1059-1999 测量不确定度评定与表示[S]. 北京:中国计量出版社, 1999.
[2]国家质量监督检验检疫总局. JJF1094-2002 测量仪器特性评定[S]. 北京:中国计量出版社, 2003.
[3]国家质量监督检验检疫总局. JJF1170-2007 负温度系数低温电阻温度计校准规范 [S]. 北京:中国计量出版社, 2007.
[4]龙包庚. 国防计量标准的建立运行与考核指南[M]. 北京: 中国计量出版社, 2003.
[5]林景星, 陈丹英. 计量基础知识[M]. 北京: 中国标准出版社, 2005.
[6]王忠兵, 吴蕾, 赵肃莹, 等. 掺杂对Ni-Mn-O 系NTC 热敏陶瓷及其电学性能的影响[J]. 硅酸盐学报, 2009 (6): 927-931.
[7]HOGE H J. Useful procedure in least squaresm and tests of some equations for thermistors[J]. Review of Scientific Instrument, 1988, 59(11): 975-979.
[8]兰玉岐, 妥万禄, 常爱民, 等. SrCoO3-δ 陶瓷材料的导电机理和低温热敏特性[J]. 电子元件与材料, 2006, (10): 44-46.
[9]中华人民共和国电子行业军用标准. SJ 50601/1-1998 MF5602型、MF5604型低温热敏电阻器详细规范[S].北京:中国计量出版社, 1998.
[10]兰玉岐, 姜迎春, 陈光明, 等. MF5602型低温热敏电阻计的特性研究[J]. 低温工程, 2011 (4): 57-59.
[11]芳侠, 邵坤鹏, 刘迪. 计量标准测量过程的统计控制的应用[J]. 电子设计工程, 2011, 19(17): 84-87.
[12]张晓光, 刘艳, 艾澜, 等. 通信开关电源的电磁兼容性[J]. 现代电子技术, 2011, 34(20): 187-189.