Abstract:
In order to obtain the parameters of plasma at thruster nozzle center position through the Langmuir probe diagnostic method, and avoid the probe staying at the spout for long time and being burned by plasma, a precise positioning and rapid reciprocating motion diagnostic system was developed by aid of LabVIEW. The system can make the probe arrive at the outlet of Hall thruster rapidly, fulfill current and voltage data acquisition in very short time, and then return to its starting location rapidly and avoid burning the probe. Compared to the data collected by conventional Langmuir probe, the data got by this system can reflect the true state of the plasma

References:

[1]DUNNING J W, HAMLEY J A, JANKOVSKY R S, et al. An overview of electric propulsion activities at NASA, AIAA2004-3328[R]. USA: AIAA, 2004.
[2]一林. 电推进发展现状[J]. 国际太空, 2004 (6): 24-26.
[3]朱毅麟. 电推进的现状与展望[J]. 上海航天, 1998, 15(003): 48-53.
[4]奥切洛, 弗拉姆. 等离子体诊断[M]. 郑少白, 译. 北京: 电子工业出版社, 1944.
[5]MILNES K A, EHLERS K W , LEUNG K N, et al. A fast Langmuir probe sweeping circuit[J]. Transaction on Plas- ma Science. 1980, 8(2): 124-126.
[6]王磊, 陶梅. 精通LabVIEW8.0[M]. 北京: 电子工业出版社, 2007.
[7]乔毅, 栾矢艳, 袁爱进. 基于LabVIEW和OPC的数据通信的实现[J]. 控制工程, 2005, 12(2): 153-155.
[8]陈树学, 刘萱. LabVIEW 宝典[M]. 北京: 电子工业出版社, 2012.
[9]MITCHNER M, KRUGER C, FONTANESI M A. 400 kHz,fast-sweep Langmuir probe for measuring plasma fluctua- tions[J]. Review of Scientific Instruments, 1999, 70(6):2681-2688.
[10]HUDDLESTONE R H, LEONARD S H. Plasma diagnos- tic techniques[M]. New York: Academic Press, 1965.
[11]PRUVIS C K. Design guidelines for assessing and con- trolling spacecraft charging effect[M]. USA: Scientific and Technical Information Branch of NASA, 1984.
[12]林榕, 毛根旺. 用Langmuir探针诊断MPT羽流[J]. 固体火箭技术, 2005, 28(2): 149-152.
[13]张宝芳. 微波等离子体的静电探针测试系统的研究设计[D]. 成都: 电子科技大学, 2008.
[14]池凌飞, 林揆训, 姚若河, 等. Langumir单探针诊断射频辉光放电等离子体及其数据处理[J]. 物理学报, 2001, 50(7): 1313-1317.
[15]MAWARDI O K. Use of Langmuir probes for low-density plasma diagnostics[J]. American Journal of Physics, 1966, 34(2): 112-120.

Memo

Memo:
-
Last Update: 1900-01-01