|Table of Contents|

Research on parasitical monofier circuit influence on liquid orbit attitude control engine solenola Valve reSlStanCe teSt(PDF)

《火箭推进》[ISSN:1672-9374/CN:CN 61-1436/V]

Issue:
2009年05期
Page:
46-49
Research Field:
测控与试验
Publishing date:

Info

Title:
Research on parasitical monofier circuit influence on liquid orbit attitude control engine solenola Valve reSlStanCe teSt
Author(s):
Pang Jun
Military Representative Office of the Navy Missile Armament Stationed in Xi7an,Xi’an 710100,China
Keywords:
parasitical monofier circuitliquid rocket enginesolenoid valvetest
PACS:
V434
DOI:
-
Abstract:
Loop resistance values by a muhifunctional tester may deviate from the real ones when test an orbit attitude control engine in a complicated electromagnetic environment with interferences.Such a test result is likely to complete distorte.The main reason is that there exists a parasitical monofier circuit during the test.The paper puts forward a method of adding shock ob— sorber capacitance in the test circuit.Test shows that this method can effectively overcome parasitical monofier.

References:

[1]液体火箭发动机设计(下)[M].北京:宇航出版社.
[2]蒋焕文,孙续.电子测量(第二版)[M].北京:中国计 量出版社.
[3][美]休泽尔,著.液体火箭发动机现代工程设计[M]. 朱宁昌.译.北京:宇航出版社.

Memo

Memo:
-
Last Update: 1900-01-01