Analysis and improvement methods for temperature measurement error of LO2 main container(PDF)

《火箭推进》[ISSN:1672-9374/CN:CN 61-1436/V]

Issue:
2015年06期
Page:
92-98
Research Field:
测控与试验
Publishing date:

Info

Title:
Analysis and improvement methods for temperature measurement error of LO2 main container
Author(s):
LEI Zhen LI Yi FU Linlin
Xi’an Aerospace Propulsion Test Technique Institute, Xi’an 710100, China
Keywords:
LO2 container layered temperature measurement error analysis improvement
PACS:
V434-34
DOI:
-
Abstract:
In order to measure the LO2 flow in the process of LO2/kerosene engine test accurately, a layered temperature measuring device composed of copper-constantan thermocouple sensors was designed and installed in the LO2 main container. According to the principle of thermocouple temperature measurement, the effects of reference junction, connectors and other factors on measured value of LO2 temperature within the container are analyzed, and some improvement measures are put forward. The measurement accuracy of LO2 temperature within container has been improved.

References:

[1]宋德华. 低温热电偶[M]. 北京: 中国计量出版社, 1992.
[2]陈静, 李培国. 补偿导线的补偿误差检定测量结果的不确定度评定[J]. 计量测试技术, 2006, 33(9): 39-40.
[3]王忠伟. 带补偿导线热电偶测温时的误差分析和修正方法[J]. 工业计量, 2008, 18(006): 34-36.
[4]郑毅然. 浅谈热电偶及其补偿导线的选型与使用[J]. 实验室科学, 2007 (1): 165-167.

[5]李忠虎. 热电偶应用问题综述[J]. 工业计量, 2007, 17(2):34-37.

[6]张红. 热电偶测量系统误差剖析及处理对策[J]. 安徽工程科技学院学报(自然科学版), 2010, 25(02): 63-66.
[7]李芸彤, 赵冰. 热电偶补偿导线的特点及使用[J]. 品牌与标准化, 2011 (Z1): 65.
[8]苗志全, 张波. 热电偶的冷端补偿方法探讨[J]. 廊坊师范学院学报(自然科学版), 2008, 8(06): 30-31.
[9]张丽. 热电偶补偿导线的正确使用[J]. 山西建筑, 2012, 38(28): 136-137.
[10]李建军, 薛宁. 液氧平均流量测量研究[J].火箭推进, 2010 (1): 67-70. LI Jianjun, XUE Ning. Research on measurement of LOX mean flow rate[J]. Journal of Rocket Propulsion, 2010 (1): 67-70.